Physical performance tests have excellent reliability in frail and non-frail patients with prostate cancer

dc.authoridozturk, ozgul/0000-0002-5207-1893
dc.authoridFEYZIOGLU, OZLEM/0000-0002-7479-4128
dc.contributor.authorFeyzioğlu, Özlem
dc.contributor.authorDinçer, Selvi
dc.contributor.authorÖzdemir, Ayşem Ecem
dc.contributor.authorÖztürk, Özgül
dc.date.accessioned2024-09-11T19:51:28Z
dc.date.available2024-09-11T19:51:28Z
dc.date.issued2024
dc.departmentİstanbul Gelişim Üniversitesien_US
dc.description.abstractPurpose: Our aim was to investigate the test-retest reliability of the 2-min walk test (2MWT), timed up and go test (TUG), and five times sit-to-stand test (FTSST) in prostate cancer (PC) patients. Methods: This study was conducted with 73 patients who were classified into two groups as frail and non-frail determined by the Geriatric-8 questionnaire. Patients performed the 2MWT, TUG, and FTSST tests for two times. The test-retest reliability of the 2MWT, TUG, and FTSST was assessed by calculating the intraclass correlation coefficient (ICC). The standard error of measurement (SEM95) and minimal detectable change (MDC95) values were calculated. Results: All tests showed excellent test-retest reliability for both groups (ICC(2.1) > 0.90). The SEM95 and MDC95 values of 2MWT were 3.09, 8.57, and 3.15 m, 8.73 m for frail and non-frail groups. The SEM95 and MDC95 values of TUG for the frail group were 0.6 and 1.66 and 0.43 and 1.19 for the non-frail group, respectively. The SEM95 and MDC95 values of FTST for the frail group were 0.68 and 1.88 and for the non-frail group 0.86 and 2.38. Conclusions: The 2MWT, TUG, and FTSST showed excellent reliability in frail and non-frail older adults with PC which can be used to assess physical performance.en_US
dc.identifier.doi10.1080/09638288.2024.2340703
dc.identifier.issn0963-8288
dc.identifier.issn1464-5165
dc.identifier.pmid38613370en_US
dc.identifier.scopus2-s2.0-85190777997en_US
dc.identifier.urihttps://doi.org/10.1080/09638288.2024.2340703
dc.identifier.urihttps://hdl.handle.net/11363/7798
dc.identifier.wosWOS:001203990400001en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.language.isoenen_US
dc.publisherTaylor & Francis Ltden_US
dc.relation.ispartofDisability And Rehabilitationen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.snmz20240903_Gen_US
dc.subjectProstate canceren_US
dc.subjectfrailen_US
dc.subjectreliabilityen_US
dc.subjectfunctional testen_US
dc.titlePhysical performance tests have excellent reliability in frail and non-frail patients with prostate canceren_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Makale / Article
Boyut:
1.56 MB
Biçim:
Adobe Portable Document Format