Cutting efficiency and corrosion resistance of heat-treated endodontic files after various disinfection protocols

dc.contributor.authorUlusoy, Şeyma
dc.contributor.authorBaştürk, Fatıma Betül
dc.contributor.authorTurkaydın, Dilek
dc.contributor.authorBerker, Yıldız Garip
dc.contributor.authorGünday, Mahir
dc.contributor.authorDurmazpınar, Parla Meva
dc.date.accessioned2024-09-11T19:50:14Z
dc.date.available2024-09-11T19:50:14Z
dc.date.issued2024
dc.departmentİstanbul Gelişim Üniversitesien_US
dc.description.abstractThe aim of this study is to evaluate the effect of various disinfection protocols on the cutting efficiency and chemical composition of ProTaper, Twisted File, Twisted File Adaptive, and Hedstrom files. Four experimental groups (n = 10) were presoaked in either enzymatic solution or 1% sodium hypochlorite for 30 min, followed by either 5 or 15 min of ultrasonic cleaning and then autoclaved. Resin-simulated canals with a single curvature of 38-40(degrees) were prepared by each instrument system. Cutting efficiency of each instrument was analyzed by subtracting the final weight from the initial weight of the resin blocks. Chemical compositions were studied by field emission scanning electron microscopy and X-ray energy-dispersive spectrometry. The cutting efficiency of Hedstrom, ProTaper, and Twisted File instruments decreased compared to their control groups (p < 0.05) whereas it did not change for Twisted File Adaptive. More corrosion was detected with longer ultrasonication time. No difference was observed regarding the pre-soaking media. Disinfection protocols exerted a significant overall effect on the performance of Hedstrom, ProTaper, and Twisted File instruments. Corrosion, microcracks, and crevices were evident on all tested instruments after disinfection protocols applied. All disinfection protocols, regardless of the pre-soaking media used or the ultrasonic cleaning time applied, have some effect on the cutting efficiency and the surface characteristics of the files.en_US
dc.description.sponsorshipMarmara University Scientific Research Projects Unit, Istanbul; [SAG-C-DUP-071015-0470]en_US
dc.description.sponsorshipThis work was supported by Marmara University Scientific Research Projects Unit, Istanbul (SAG-C-DUP-071015-0470).en_US
dc.identifier.doi10.1007/s10266-023-00896-9
dc.identifier.endpage854en_US
dc.identifier.issn1618-1247
dc.identifier.issn1618-1255
dc.identifier.issue3en_US
dc.identifier.pmid38381265en_US
dc.identifier.scopus2-s2.0-85185494879en_US
dc.identifier.startpage847en_US
dc.identifier.urihttps://doi.org/10.1007/s10266-023-00896-9
dc.identifier.urihttps://hdl.handle.net/11363/7592
dc.identifier.volume112en_US
dc.identifier.wosWOS:001171619600001en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofOdontologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.snmz20240903_Gen_US
dc.subjectCorrosionen_US
dc.subjectCutting efficiencyen_US
dc.subjectDisinfectionen_US
dc.subjectM-wireen_US
dc.subjectSterilizationen_US
dc.titleCutting efficiency and corrosion resistance of heat-treated endodontic files after various disinfection protocolsen_US