Validity and reliability of velocity and power measures provided by the Vitruve linear position transducer

dc.authoridhttps://orcid.org/0000-0003-1736-6482
dc.authoridhttps://orcid.org/0000-0002-1743-5989
dc.authoridhttps://orcid.org/0000-0002-2185-6436
dc.authoridhttps://orcid.org/0000-0001-5535-2087
dc.authoridhttps://orcid.org/0000-0002-0900-9410
dc.contributor.authorRuiz-Alias, Santiago A.
dc.contributor.authorŞentürk, Deniz
dc.contributor.authorAkyıldız, Zeki
dc.contributor.authorÇetin, Onat
dc.contributor.authorKaya, Selman
dc.contributor.authorPerez-Castilla, Alejandro
dc.contributor.authorJukic, Ivan
dc.date.accessioned2025-06-02T08:45:15Z
dc.date.available2025-06-02T08:45:15Z
dc.date.issued2024
dc.departmentBeden Eğitimi ve Spor Yüksekokulu
dc.description.abstractThis study aimed to determine the validity and between-day reliability of the mean velocity (MV), peak velocity (PV), mean power (MP), and peak power (PP) provided by the Vitruve linear position transducer at different submaximal loads in the free-weight and Smith machine back squat using GymAware as a reference point. Fourteen male sports science students (free-weight back squat one-repetition maximum [1RM]: 132.5 ± 28.5 kg, Smith machine back squat 1RM: 163.9 ± 30.4 kg) performed six experimental sessions, twice per week with 72 hours of rest. The first two included the assessment of the 1RM of both exercises. In the four remaining, both linear position transducers were simultaneously used to record MV, PV, MP, PP of each repetition during an incremental load test (i.e., 20, 40, 60, 80, 90% 1RM) with three minutes of rest between sets. Vitruve displayed both fixed and proportional bias for certain relative loads across all variables. Vitruve did not meet the validity criteria for all (MV, PP) or at least two (MP, PV) relative loads (Coefficient of variation [CV] > 10%; Pearson correlation < 0.70; Effect size > 0.60). MV, PV, MP, and PP recorded by Vitruve displayed acceptable reliability (CV < 10%) with superior reliability observed during a Smith Machine compared to free-weight back squat, and for velocity compared to power variables. Considering GymAware as a reference point, Vitruve was not valid for measuring velocity and power outcomes. Acceptable validity was observed only for PV in the Smith machine back squat, while the other variables—regardless of relative loads and exercise modes—were mostly inaccurate. All variables demonstrated acceptable reliability, with greater reliability noted in the Smith machine compared to the free-weight back squat exercise mode.
dc.identifier.citationRuiz-Alias SA, Şentu¨rk D, Akyildiz Z, C¸etin O, Kaya S, Pe´rez-Castilla A, et al. (2024) Validity and reliability of velocity and power measures provided by the Vitruve linear position transducer. PLoS ONE 19(10): e0312348. https://doi.org/ 10.1371/journal.pone.0312348
dc.identifier.doihttps://doi.org/ 10.1371/journal.pone.0312348
dc.identifier.issn1932-6203
dc.identifier.issue10
dc.identifier.urihttps://hdl.handle.net/11363/9845
dc.identifier.volume19
dc.identifier.wos001345605200014
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.institutionauthorŞentürk, Deniz
dc.institutionauthoridhttps://orcid.org/0000-0003-1736-6482
dc.language.isoen
dc.publisherPUBLIC LIBRARY SCIENCE, 1160 BATTERY STREET, STE 100, SAN FRANCISCO, CA 94111
dc.relation.ispartofPLOS ONE
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleValidity and reliability of velocity and power measures provided by the Vitruve linear position transducer
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Makale / Article
Boyut:
1.02 MB
Biçim:
Adobe Portable Document Format
Lisans paketi
Listeleniyor 1 - 1 / 1
[ N/A ]
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: