Tracking failure and recurrence plot analysis for three different levels in the discharge on epoxy resin

[ N/A ]

Tarih

2017

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Institute of Electrical and Electronics Engineers Inc.

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Electric energy requirement is increasing day by day, so excessive demand for the transmission of high voltage and current has brought problems in high voltage insulation. The polymers used for electrical insulation in the external environment is exposed to environmental conditions. In this paper, ASTM D5288 standards is used to simulate this environmental stresses. In this standard tracking failure of pure epoxy resin samples are investigated. During the expriment, 3., 20. and 50. drop the instant evaporation mechanism obtained through discharge currents, that they were analyzed by the recurrence plot method. © 2016 The Chamber of Turkish Electrical Engineers.

Açıklama

2016 National Conference on Electrical, Electronics and Biomedical Engineering, ELECO 2016 -- 1 December 2016 through 3 December 2016 -- Bursa -- 126446

Anahtar Kelimeler

Biomedical engineering; Electric insulation; Epoxy resins; Discharge currents; Electric energies; Environmental conditions; Environmental stress; External environments; High voltage insulation; Recurrence plot; Tracking failure; Electronic medical equipment

Kaynak

2016 National Conference on Electrical, Electronics and Biomedical Engineering, ELECO 2016