Assessing the Gymaware RS Linear Position Transducer Reliability and Validity in Measuring Countermovement Jump Height

dc.authoridhttps://orcid.org/0000-0003-1736-6482
dc.contributor.authorAkyıldız, Zeki
dc.contributor.authorŞentürk, Deniz
dc.date.accessioned2026-08-20T12:42:25Z
dc.date.issued2026
dc.departmentSpor Bilimleri Fakültesi
dc.description.abstractThis study evaluated the concurrent validity and intra-device reliability of a linear position transducer (LPT) for counter-movement jump (CMJ) height. Twenty-six subjects (22.21 ± 5.3 years) performed five CMJs using a force plate (Forcedecks) concurrently with the LPT to test validity. A statistically significant difference was found between the force plate and Gymaware units. Although there are differences between strength platforms and Gymaware units, there is no difference between the Gymaware units. Bland-Altman analysis for validity revealed that LPT overestimated jump height for CMJ in both units, Gymaware RS unit 1 and Gymaware RS unit 2. Gymaware RS equipment, like the force platform, provides reliable measurement data. The Forcedecks force platform, Gymaware RS unit 1, and Gymaware RS unit 2 provide data below 5% CV. The Gymaware RS overestimates jump height, but it is a reliable tool for tracking changes in jump height to measure performance improvement and monitor fatigue.
dc.identifier.doi10.1080/1091367X.2026.2699718
dc.identifier.issn1091-367X
dc.identifier.scopus2-s2.0-105044012873
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://hdl.handle.net/11363/12341
dc.indekslendigikaynakScopus
dc.institutionauthorŞentürk, Deniz
dc.institutionauthoridhttps://orcid.org/0000-0003-1736-6482
dc.language.isoen
dc.publisherRoutledge
dc.relation.ispartofMeasurement in Physical Education and Exercise Science
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCountermovement Jump
dc.subjectlinear position transducer
dc.subjectmeasurement
dc.subjectvalidity
dc.subjectreliability
dc.titleAssessing the Gymaware RS Linear Position Transducer Reliability and Validity in Measuring Countermovement Jump Height
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Makale / Article.pdf
Boyut:
4.34 MB
Biçim:
Adobe Portable Document Format

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: