Periodontal Mechanoreceptor Contribution to Minimal Holding Force Between Incisor Teeth

dc.authoridhttps://orcid.org/0000-0002-6555-4800
dc.authoridhttps://orcid.org/0000-0002-0720-3447
dc.authoridhttps://orcid.org/0000-0003-4371-5455
dc.authoridhttps://orcid.org/0009-0007-9333-9087
dc.authoridhttps://orcid.org/0000-0003-0850-5946
dc.authoridhttps://orcid.org/0000-0002-7462-1358
dc.authoridhttps://orcid.org/0000-0001-9962-075X
dc.contributor.authorOğuz, Elif Ezgi
dc.contributor.authorÖzlü Uçan, Gülfem
dc.contributor.authorKarakış Akcan, Serap
dc.contributor.authorMihmanlı, Ahmet
dc.contributor.authorÇetinkaya, Nursuna Büşra
dc.contributor.authorWeisskircher, Hans-Werner
dc.contributor.authorYıldız, Nilgün
dc.contributor.authorKaracan, İlhan
dc.contributor.authorTürker, Kemal Sıtkı
dc.date.accessioned2026-09-25T07:53:49Z
dc.date.issued2026
dc.departmentDiş Hekimliği Fakültesi
dc.description.abstractBackground: The functional importance of periodontal mechanoreceptors (PMRs) is highlighted by impaired force control when periodontal input is reduced or absent. Previous studies used handheld transducers to measure the minimum holding force between the incisors. In the present study, a high-resolution force transducer was held passively between the incisors against gravity. Objective: To quantify the contribution of anterior PMRs to minimum holding force and examine the effects of body position and periodontal health. Methods: Twenty healthy adults (12 females, 8 males; 23.2±1.9 years) participated in this repeated-measures study. A lightweight FlexiForce transducer was positioned passively between the incisors and held against gravity. Minimum holding force was measured in sitting and prone positions before and after local anaesthesia (LA) of the incisors. Data were analysed using linear mixed models and correlation analyses. Results: Mean minimum holding force in the sitting position increased from 0.63N to 1.87N following LA. In comparison, prone values increased from 1.23N to 2.63N. Significant main effects were observed for position (p=0.027) and LA (p=0.036), with no interaction effect (p=0.848). Periodontal health was significantly associated with holding force only when LA was present (R2=0.234, p=0.031). Conclusion: Reduced periodontal sensory input from the anterior dentition may impair early detection of food properties, potentially compromising feedforward control during mastication. These findings highlight the functional importance of periodontal integrity and the need to retain healthy teeth in restorative and orthodontic treatment planning.
dc.identifier.doi10.1111/joor.70300
dc.identifier.issn0305-182X
dc.identifier.issn1365-2842
dc.identifier.urihttps://hdl.handle.net/11363/12671
dc.identifier.wos001876860500001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.institutionauthorÖzlü Uçan, Gülfem
dc.institutionauthorKarakış Akcan, Serap
dc.institutionauthorMihmanlı, Ahmet
dc.institutionauthorÇetinkaya, Nursuna Büşra
dc.institutionauthorYıldız, Nilgün
dc.institutionauthorTürker, Kemal Sıtkı
dc.institutionauthoridhttps://orcid.org/0000-0002-0720-3447
dc.institutionauthoridhttps://orcid.org/0000-0003-4371-5455
dc.institutionauthoridhttps://orcid.org/0009-0007-9333-9087
dc.institutionauthoridhttps://orcid.org/0000-0003-0850-5946
dc.institutionauthoridhttps://orcid.org/0000-0001-9962-075X
dc.language.isoen
dc.publisherWILEY, 111 RIVER ST, HOBOKEN 07030-5774, NJ
dc.relation.ispartofJOURNAL OF ORAL REHABILITATION
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectGravity
dc.subjectincisor teeth
dc.subjectlocal anaesthetics
dc.subjectminimum holding force
dc.subjectperiodontal mechanoreceptors
dc.titlePeriodontal Mechanoreceptor Contribution to Minimal Holding Force Between Incisor Teeth
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Makale / Article.pdf
Boyut:
565.03 KB
Biçim:
Adobe Portable Document Format

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: