    Tracking failure and recurrence plot analysis for three different levels in the discharge on epoxy resin
    (Institute of Electrical and Electronics Engineers Inc., 2017) Ispirli, Mehmet Murat; Yilmaz, Aysel Ersoy
    Electric energy requirement is increasing day by day, so excessive demand for the transmission of high voltage and current has brought problems in high voltage insulation. The polymers used for electrical insulation in the external environment is exposed to environmental conditions. In this paper, ASTM D5288 standards is used to simulate this environmental stresses. In this standard tracking failure of pure epoxy resin samples are investigated. During the expriment, 3., 20. and 50. drop the instant evaporation mechanism obtained through discharge currents, that they were analyzed by the recurrence plot method. © 2016 The Chamber of Turkish Electrical Engineers.
  • [ N/A ]
    Öğe
    Tracking failure and recurrence plot analysis for three different levels in the discharge on epoxy resin
    (IEEE, 2016) Ispirli, Mehmet Murat; Yilmaz, Aysel Ersoy
    Electric energy requirement is increasing day by day, so excessive demand for the transmission of high voltage and current has brought problems in high voltage insulation. The polymers used for electrical insulation in the external environment is exposed to environmental conditions. In this paper, ASTM D5288 standards is used to simulate this environmental stresses. In this standard tracking failure of pure epoxy resin samples are investigated. During the expriment, 3., 20. and 50. drop the instant evaporation mechanism obtained through discharge currents, that they were analyzed by the recurrence plot method.

| İstanbul Gelişim Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Cihangir Mahallesi, Şehit Jandarma Komando Er Hakan Öner Sokak, No:1, Avcılar, İstanbul, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim