Economically Advantageous Two-Stage Heat Exchanger Configuration for High-Temperature Exhaust Heat Management in Multi-Generation System Utilized in Heat-Driven Humidification-Dehumidification Desalination Unit and sCO2 Cycle Leveraging Metaheuristic Bat Algorithm

dc.contributor.authorLi, Yonghui
dc.contributor.authorBasem, Ali
dc.contributor.authorBalla, Hyder H. Abed
dc.contributor.authorKhlifi, Mohamed Arbi
dc.contributor.authorZhang, Haibo
dc.contributor.authorAbu-Zinadah, Hanaa
dc.contributor.authorBu Sinnah, Zainab Ali
dc.contributor.authorNorberdiyeva, Muyassar
dc.contributor.authorFouad, Yasser
dc.contributor.authorMahariq, Ibrahim
dc.date.accessioned2026-09-29T07:03:44Z
dc.date.issued2026
dc.departmentMühendislik ve Mimarlık Fakültesi
dc.description.abstractThis study proposes value-oriented thermal management in a sustainable biomass-based freshwater and hydrogen production system integrating a humidification–dehumidification (HDH) desalination unit with a supercritical CO₂ Brayton cycle and PEM water electrolysis, driven by rice straw biomass. A comprehensive thermodynamic model evaluates system performance, with particular emphasis on freshwater generation under varying operating conditions, including gas turbine pressure ratio, turbine inlet temperature, and biomass feed rate. High-temperature exhaust gases from the gas turbine transfer their thermal energy through two heat exchangers as a cost-effective approach. The first heat exchanger supplies heat to drive the supercritical CO₂ (sCO₂) Brayton cycle, generating additional power. Within the sCO₂ cycle, an internal heat exchanger provides heated air for residential space-heating applications. The second heat exchanger recovers residual exhaust heat to drive the HDH desalination cycle, producing freshwater. The system simultaneously delivers electricity, freshwater, hot air, hydrogen, and oxygen. Performance analyses indicate that increasing the gas turbine pressure ratio enhances electrical power and hydrogen production while reducing thermal outputs such as freshwater and hot air. Conversely, higher turbine inlet temperatures favor freshwater and hot air generation. Results show that freshwater production increases significantly with higher turbine inlet temperature and biomass feed rate, reaching up to 216.8 L/h and 235.3 L/h, while higher pressure ratios reduce water yield due to enhanced energy extraction in the power cycle. A metaheuristic bat algorithm is used for multi-objective optimization to maximize freshwater and hydrogen production while improving overall system efficiency. An optimal configuration achieves high freshwater yield, considerable hydrogen generation, and efficiency exceeding 80%.
dc.identifier.doi10.1016/j.icheatmasstransfer.2026.111615
dc.identifier.issn0735-1933
dc.identifier.issn1879-0178
dc.identifier.issue2
dc.identifier.urihttps://hdl.handle.net/11363/12694
dc.identifier.volume178
dc.identifier.wos001787260400001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.institutionauthorMahariq, Ibrahim
dc.language.isoen
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD, THE BOULEVARD, LANGFORD LANE, KIDLINGTON, OXFORD OX5 1GB, ENGLAND
dc.relation.ispartofINTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectThermal management
dc.subjectHeat recovery
dc.subjectHeat-driven
dc.subjectHDH desalination
dc.subjectGas turbine
dc.subjectMetaheuristic bat algorithm
dc.subjectCost-effective framework
dc.titleEconomically Advantageous Two-Stage Heat Exchanger Configuration for High-Temperature Exhaust Heat Management in Multi-Generation System Utilized in Heat-Driven Humidification-Dehumidification Desalination Unit and sCO2 Cycle Leveraging Metaheuristic Bat Algorithm
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Makale / Article.pdf
Boyut:
7.14 MB
Biçim:
Adobe Portable Document Format

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: