A study on the performance of the various refrigerants on the two-stage vapor compression refrigeration system with a flash chamber for ships

dc.authoridhttps://orcid.org/0000-0002-0037-8332
dc.contributor.authorKepekçi, Haydar İzzettin
dc.date.accessioned2025-08-12T12:44:44Z
dc.date.available2025-08-12T12:44:44Z
dc.date.issued2025
dc.departmentMühendislik ve Mimarlık Fakültesi
dc.description.abstractThe climate crisis and rising electricity costs demand efficient ship cooling systems. This study analyzes a two-stage compression refrigeration system with a flash chamber using seven refrigerants: R134a, R404a, R407c, R32, R717, R1234yf, and R1234zee. At an intermediate temperature of 20◦C, R717 achieved the highest cooling capacity per unit mass (1063 kW/kg), while R32 had the highest per unit suction volume (5207.68 kW/m3). R407c exhibited the highest Coefficient of Performance (COP) (4.643) under the same conditions. Thermodynamic analysis via Engineering Equations Solver (EES) reveals the influence of refrigerants, temperatures, and compressor efficiencies, offering insights for optimizing ship refrigeration to enhance energy efficiency and minimize environmental impact.
dc.identifier.doihttps://doi.org/10.1093/ijlct/ctaf049
dc.identifier.endpage701
dc.identifier.issn1748-1317
dc.identifier.issn1748-1325
dc.identifier.startpage690
dc.identifier.urihttps://hdl.handle.net/11363/10265
dc.identifier.volume20
dc.identifier.wos001447562800001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.institutionauthorKepekçi, Haydar İzzettin
dc.institutionauthoridhttps://orcid.org/0000-0002-0037-8332
dc.language.isoen
dc.publisherOXFORD UNIV PRESS, GREAT CLARENDON ST, OXFORD OX2 6DP, ENGLAND
dc.relation.ispartofINTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjecttwo-stage compression
dc.subjectrefrigeration
dc.subjectflash chamber
dc.subjectship cooling systems
dc.titleA study on the performance of the various refrigerants on the two-stage vapor compression refrigeration system with a flash chamber for ships
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Makale / Article
Boyut:
1.65 MB
Biçim:
Adobe Portable Document Format
Lisans paketi
Listeleniyor 1 - 1 / 1
[ N/A ]
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: