Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Khatrush, Suleiman" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Laboratory evaluation of undrained shear strength of a soft fine grained soils
    (İstanbul Gelişim Üniversitesi Yayınları / Istanbul Gelisim University Press, 2021) Khatrush, Suleiman; El-Gehani, Ghassan
    The determination of undrained shear strength of soils is commonly achieved using triaxial testing in which specimen is carefully prepared before testing to maintain its original field condition. However, for soft soils preparing and handling specimens without causing any disturbance is a difficult job and may not always be successful. Other laboratory testing techniques can be adopted provided they can produce reliable results for such cases and can overcome the problem of pretest preparation process and hence avoiding any alteration of sample field condition. Extensive laboratory investigation on a soft marine soil recovered from sea bed offshore of Benghazi city, the testing program involves investigation of the basic geotechnical properties, focusing specifically on the determination of the undrained shear strength of such soils as determined by both the conventional unconsolidated undrained triaxial testing (UU) and the simple laboratory vane shear testing device (Miniature shear vane MV). The resulting shear strength obtained by UU-triaxial test, and resulting shear strength measured by Miniature shear vane MV were examined, compared and discussed on the light of other research works. Furthermore, the problems faced during testing soft samples in triaxial apparatus was also presented. The resulting undrained shear strength obtained by UU-triaxial test was found generally lower than that produced by Miniature shear vane MV which is attributed to sample disturbance before testing in triaxial. The study also demonstrates that despite of high scatter, the undrained shear strength obtained by MV can be reasonably comparable with the results of other investigations on soft soils

| İstanbul Gelişim Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Cihangir Mahallesi, Şehit Jandarma Komando Er Hakan Öner Sokak, No:1, Avcılar, İstanbul, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim