Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Arslan Nazan, Ali" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Comparative evaluation of the performance of orthodontic retainers using different surface protocols: an in vitro study
    (SPRINGER LONDON LTD, 236 GRAYS INN RD, 6TH FLOOR, LONDON WC1X 8HL, ENGLAND, 2025) Kurnaz, Merve; Arslan Nazan, Ali; Eraydın, Feyza
    This study aims to assess the in vitro durability of Nitinol retainers, manufactured using computer-aided methods with hydrophilic or superhydrophilic surfaces to reduce debonding, alongside a commonly used composite adhesive. The 112 lower incisor teeth were embedded in blocks in pairs. Retainer wires were made up of 0.018×0.018 inch Nickel Titanium alloy(G4™ Nickel Titanium G&H Orthodontics, USA) by bending a robot arm. A total of 16 teeth(8 blocks) were used for each of the mentioned 7 groups Ni-Ti Retainer; Laser Textured Ni-Ti Retainer; Laser Texturing and Atmospheric Plasma Applicated Ni-Ti Retainer; Atmospheric Plasma Applicated Ni-Ti Retainer; Laser Texturing and Atmospheric Plasma Applicated Ni-Ti Retainer*2; Laser Texturing and Atmospheric Plasma Applicated Ni-Ti Retainer*3; SS-0.0018“(Morelli, Brazil). Transbond LR(3 M Unitek, California) was used. The shear bond strength tests were conducted. The Kruskal-Wallis H test was employed, pairwise comparisons followed by Dunn’s test with Bonferroni correction as a post hoc analysis. There was no statistically significant difference between the groups for maximum force and maximum stress(p>0.05). However, a significant difference was found in maximum elongation (p:0.0023). Pairwise comparisons highlighted significantly higher elongation values in the SS-0.0018” group. The stainless-steel wire demonstrated higher elongation values, which may offer clinical advantages in cases with higher occlusal forces and periodontal problems due to its material flexibility. Laser Texturing and Atmospheric Plasma Applied Ni-Ti Retainers exhibited higher test performance. Surface treatments applied to CAD/CAM retainers can provide an advantage by enhancing bond strength, potentially reducing the risk of debonding. These findings underline the importance of material selection and surface treatments in optimizing fixed retention strategies for long-term clinical success.

| İstanbul Gelişim Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Cihangir Mahallesi, Şehit Jandarma Komando Er Hakan Öner Sokak, No:1, Avcılar, İstanbul, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim