Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorSelçuk, Tuba
dc.contributor.authorOtçu, Hafize
dc.contributor.authorYüceler, Zeyneb
dc.contributor.authorBilgili, Çiğdem
dc.contributor.authorBulakçı, Mesut
dc.contributor.authorSavaş, Yıldıray
dc.contributor.authorÇelik, Ömer
dc.date.accessioned2023-10-05T08:35:56Z
dc.date.available2023-10-05T08:35:56Z
dc.date.issued2016en_US
dc.identifier.issn2146-3123
dc.identifier.issn2146-3131
dc.identifier.urihttps://hdl.handle.net/11363/5760
dc.description.abstractBackground: Early detection of coronary artery disease (CAD) is important because of the high morbidity and mortality rates. As invasive coronary angiography (ICA) is an invasive procedure, an alternative diagnostic method; coronary computed tomography angiography (CTA), has become more widely used by the improvements in detector technology. Aims: In this study, we aimed to examine the accuracy and image quality of high-pitch 128-slice dual-source CTA taking the ICA as reference technique. We also aimed to compare the accuracy and image quality between different heart rate groups of >70 beates per minute (bpm) and ≤70 bpm. Study Design: Retrospective cross-sectional study. Methods: Among 450 patients who underwent coronary CTA with the FLASH spiral technique, performed with a second generation dual-source computed tomography device with a pitch value of 3.2, 102 patients without stent and/or bypass surgery history and clinically suspected coronary artery disease who underwent ICA within 15 days were enrolled. Image quality was assessed by two independent radiologists using a 4-point scale (1=absence of any artifacts- 4=non-evaluable). A stenosis >50% was considered significant on a per-segment, per-vessel, and per-patient basis and ICA was considered the reference method. Radiation doses were determined using dose length product (DLP) values detected by the computed tomography (CT) device. In addition, patients were classified into two groups according to their heart rates as ≤70 bpm (73 patients) and >70 bpm (29 patients). The relation between the diagnostic accuracy and heart rate groups were evaluated. Results: Overall, 1495 (98%) coronary segments were diagnostic in 102 patients (32 male, 70 female, mean heart rate: 65 bpm). There was a significant correlation between image quality and mean heart rate in the right coronary artery (RCA) segments. The effective radiation dose was 0.98±0.09 mili Sievert (mSv). On a per-patient basis, sensitivity, specificity, and positive and negative predictive values were 93.8%, 88.8%, 93.8% and 88.8%, respectively. These values were also similar in per-vessel and per-segment basis. Two different groups categorized by mean heart rate had almost similar results in terms of the diagnostic power of dual-source CTA. Conclusion: CTA with a high pitch value is a reliable, non-invasive diagnostic method that can CAD with low radiation doses not only in patients with a heart rate below 70 bpm, but also in patients with higher heart rates.en_US
dc.language.isoengen_US
dc.publisherErkan Moren_US
dc.relation.isversionof10.5152/balkanmedj.2016.16220en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectComputed tomography angiographyen_US
dc.subjectCoronary arteriesen_US
dc.subjectHigh-pitchen_US
dc.subjectLow radiation doseen_US
dc.subjectHeart rateen_US
dc.titleEffectiveness of Using Dual-source CT and the Upshot it creates on Both Heart Rate and Image Qualityen_US
dc.typearticleen_US
dc.relation.ispartofBalkan Medical Journalen_US
dc.departmentSağlık Bilimleri Fakültesien_US
dc.authoridhttps://orcid.org/0000-0002-2388-1715en_US
dc.authoridhttps://orcid.org/0000-0003-0849-0705en_US
dc.authoridhttps://orcid.org/0000-0003-0993-6465en_US
dc.identifier.volume33en_US
dc.identifier.issue3en_US
dc.identifier.startpage283en_US
dc.identifier.endpage293en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorSelçuk, Tuba


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster

info:eu-repo/semantics/openAccess
Aksi belirtilmediği sürece bu öğenin lisansı: info:eu-repo/semantics/openAccess