Determination of Glucose using Flow Injection Analysis and Borate Selective Electrode
Özet
This study focuses on the development of a flow injection analysis method that performs nonenzymatic
glucose measurement. It is aimed to develop a more economical blood glucose monitoring system by
measuring the instant blood glucose level indirectly with borate based ion selective electrode. A nonenzymatic electrode based on carbon nanotube-silver borate (CNT-SB) composite electrode was
developed and integrated into a flow injection analysis system as a detector, and glucose measurement
was performed. Potentiometric measurement was made with this detection chamber. Heights of
potentiometric peaks obtained were used for the determination of the amount of glucose in blood
samples. Repeated injections were tested by using a mini-sized separation column as stationary phase
and successful results were obtained. In addition, boronic acid solution was used as a carrier solution in
the system, and it is predicted to be more accessible and simple method than the present non-enzymatic
methods as it has ability at neutral pH conditions. The developed glucose measurement system was
simple, economic and fast.
Cilt
15Sayı
12Bağlantı
https://hdl.handle.net/11363/5655Koleksiyonlar
Aşağıdaki lisans dosyası bu öğe ile ilişkilidir: