Advanced Search

Show simple item record

dc.contributor.authorUtkan, Ali
dc.contributor.authorİğdir, Volkan
dc.contributor.authorArslan, Aydın
dc.contributor.authorŞen Esmer, Tülin
dc.contributor.authorÖzkurt, Bülent
dc.date.accessioned2023-11-12T17:09:59Z
dc.date.available2023-11-12T17:09:59Z
dc.date.issued2019en_US
dc.identifier.issn1305-8282
dc.identifier.issn1309-0313
dc.identifier.urihttps://hdl.handle.net/11363/6380
dc.description.abstractObjectives: This study aims to investigate the fitness of two anatomic distal femoral plates with cadaveric femurs and to show whether current plates optimally match each femur. Materials and methods: Two different sets of plates with five, seven and nine shaft holes were applicated on 62 cadaveric femurs. Ball clay was molded onto the entire inner surfaces of the plates and then the plates were fixed to the bones using two self-locking nylon cable zip ties. The volume of ball clay sandwiched in between the plate and bone was calculated and used as a quantitative fit parameter. Data of each plate were analyzed separately. Results: Using Double Medical Technology IncorporatedTM plates, the mean plate to bone volumes were calculated as 8.4 mL (range, 5-14 mL), 10.0 mL (range, 6-17 mL), and 13.1 mL (range, 7-25 mL) in five, seven and nine-hole plates, respectively. Using Zimmer Biomet IncorporatedTM plates, the mean volumes were 10.5 mL (range, 6-21 mL), 12.7 mL (range, 7-22 mL) and 16.3 mL (range, 8-30 mL) in five, seven and nine-hole plates, respectively. Within each group, the measurements were significantly correlated positively with femoral length. Conclusion: Optimal fit may not be achieved in each femur using current distal femoral plate implant sets. Thus additional sizes of plates should be supplied in the implant sets.en_US
dc.description.abstractAmaç: Bu çalışmada iki anatomik distal femur plağının kadavra femurlarıyla uyumluluğu araştırıldı ve mevcut plakların her femura en iyi şekilde uyup uymadığı gösterildi. Gereç ve yöntemler: Gövdesinde beş, yedi ve dokuz deliği olan iki farklı plak seti 62 kadavra femuruna uygulandı. Plakların tüm iç yüzeyleri seramik çamuruyla sıvandı, sonra plaklar iki adet kendinden kilitli naylon kablo bağı kullanılarak kemiklere sabitlendi. Plak ve kemik arasında sıkıştırılan seramik çamurunun hacmi hesaplanarak nicel uyum parametresi olarak kullanıldı. Her plağın verileri ayrı ayrı analiz edildi. Bulgular: Double Medical Technology IncorporatedTM plakları kullanıldığında, plak ile kemik arasındaki hacim ortalamaları beş, yedi ve dokuz delikli plaklarda sırasıyla 8.4 mL (dağılım, 5-14 mL), 10.0 mL (dağılım, 6-17 mL) ve 13.1 mL (dağılım, 7-25 mL) olarak hesaplandı. Zimmer Biomet IncorporatedTM plakları kullanıldığında, hacim ortalamaları beş, yedi ve dokuz delikli plaklarda sırasıyla 10.5 mL (dağılım, 6-21 mL), 12.7 mL (dağılım, 7-22 mL) ve 16.3 mL (dağılım, 8-30 mL) idi. Her grup içinde, ölçümler femur uzunluğu ile pozitif olarak anlamlı şekilde bağıntılı idi. Sonuç: Mevcut distal femur plağı implant setleri kullanılarak her femurda en iyi uyum elde edilemeyebilir. Bu nedenle, implant setlerinde ilave boyutlarda plaklar sağlanmalıdır.en_US
dc.language.isoengen_US
dc.publisherBayçınar Tıbbi Yayıncılıken_US
dc.relation.isversionof10.5606/ehc.2019.64940en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectcadaveric dry femur boneen_US
dc.subjectcongruency of locking platesen_US
dc.subjectdistal femur plateen_US
dc.subjectfit assessment parameteren_US
dc.subjectplate bone fiten_US
dc.subjectprecontoured plate fiten_US
dc.subjectquantitative fit parameteren_US
dc.subjectkadavra kuru femur kemiğien_US
dc.subjectkilitli plakların uygunluğuen_US
dc.subjectdistal femur plağıen_US
dc.subjectuyum değerlendirme parametresien_US
dc.subjectplak kemik uyumuen_US
dc.subjectönceden şekillendirilmiş plak uyumuen_US
dc.subjectnicel uyum parametresien_US
dc.titleFit assessment of two different anatomically contoured distal femur plate sets on cadaveric bonesen_US
dc.title.alternativeİki farklı anatomik şekillendirilmiş distal femur plak setinin kadavra kemikleriyle uyumunun değerlendirilmesien_US
dc.typearticleen_US
dc.relation.ispartofEklem Hastalıkları ve Cerrahisi Dergisi (Eski Adı: Artroplasti Artroskopik Cerrahi Derg.)en_US
dc.departmentSağlık Bilimleri Fakültesien_US
dc.authoridhttps://orcid.org/0000-0002-3653-3998en_US
dc.authoridhttps://orcid.org/0000-0002-7599-8923en_US
dc.authoridhttps://orcid.org/0000-0001-5036-517Xen_US
dc.authoridhttps://orcid.org/0000-0002-1879-1790en_US
dc.authoridhttps://orcid.org/0000-0002-6135-1870en_US
dc.identifier.volume30en_US
dc.identifier.issue2en_US
dc.identifier.startpage137en_US
dc.identifier.endpage142en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorArslan, Aydın


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess